THE NEW ADVANCE TECHNOLOGY : SCALE REMOVAL
DEVICE (SRD) SERIES
Application
Application
The SRD Series is widely applied across various industries, including:
- Semiconductor manufacturing
- Injection molding facilities
- Data centers and commercial buildings
- Power plants
- Automotive manufacturing
- HVAC systems
- Hospitals, resort, malls & universities
Applicable equipment includes cooling towers, chillers, heat exchangers, steam boiler system, water-cooled compressors, and related cooling water systems.
Product characterization
Product characterization
Convenient operation screen
Electrolytic method
Remote control system
Screen composition
Screen composition
Remote control system
Remote control system
System composition
System composition
Specification
Specification
Scale capture and installation effect
Scale capture and installation effect
The automatic scale removal device checks the scale capture in manual mode for a certain period after installation and then automatically discharges it. In addition, the size and the shape of scale are different from those that are captured in manual mode when automatically discharged.
As a result of comparison before and after the operation of the cooling tower eliminator in the bottled water plant in Korea, it can be seen that the scale of the surface was removed 35 days after operation
This is a comparison of before and after SRD operation of the heat exchanger intercooler. It can be seen that the surface scale and slime were removed.
Installation of O Corporation's Scale Removal Device in Eumseong
Installation of O Corporation's Scale Removal Device in Eumseong
Model name: SRD-500A x 3 units
Operating time: 2020 July 20th ~ Now
Scale capture check date: 2020 August 25th
Installing facility: cooling tower 500RT x 2 units, 250RT x 2 units
The feature of scale captured in the strainer after the operation of the scale removal device (After four weeks of operation)
Turn off the automatic discharging function for three months and check the capture status and set the automatic discharging function.
Before and after comparison of operating the cooling tower Eliminator in Pyungchang H Corporation.(After 35 days)
Before and after comparison of operating the cooling tower Eliminator in Pyungchang H Corporation.(After 35 days)
Removal of scale from the surface is completed.
Before and after comparison of scale removal from the heat exchanging machine in Phochon P Corporation (Intercooler)
Before and after comparison of scale removal from the heat exchanging machine in Phochon P Corporation (Intercooler)
Components and Analysis Result of Captured Scale
Components and Analysis Result of Captured Scale